Release Notes > Maintenance Fixes > Fixed in 31.0.10.0
Fixed in 31.0.10.0
Item
Description
Bug ID
1.  
Alteon sends multiple requests to the RADIUS server for one login to WBM.
prod00270429
2.  
When submitting the SECWA configuration, AppWall issued the following error:
You are not authorized to edit this Web Application.
prod00265178
3.  
When the user enabled vmasport and entered Apply, Alteon rebooted due to a software panic.
prod00270547
4.  
A real server under /info/slb/group displayed in the BLOCKED state. When a group was not attached to any service or filter, no svc-pool entry waa created for it. As a result, the wrong group was displayed with the /info/slb/group command.
Fix: If at least one group is configured for the real server with no svc-entry corresponding to the group, the svc-pool entry is preserved with the default health check and group ID. In addition, if there is not any svc-entry corresponding to the group that is being queried, the default health check for the real server is displayed.
prod00272031
5.  
When reading techdata on a ADC-VX, the device crashed and the vADCs rebooted.
prod00270910
6.  
In a filter configuration, the default value of "matchdev" diffred between WBM and CLI.
prod00269978
7.  
Out-of-order TCPv6 segments from the client to the MP caused a panic.
prod00270263
8.  
Using the command /info/slb/sess/dump, the configuration sync fails while dumping huge SLB sessions onto the console.
prod00271199
9.  
In an SLB environment, when the primary group became operational, the backup group's session table was removed.
As part of the fix, the session entry is removed if the real server is not enabled under the group. In this scenario, this condition failed because the session's real server that is backed up is removed from the group when the primary real server becomes operational. This leads to removal of the backup real server's session entry when the primary real server comes up.
prod00270085
10.  
In a hot-standby VRRP environment, when port 1 was disabled on the backup, Alteon attempted to disable the port as part of the hot standby algorithm irrespective of the current status of port. The functions called during the flow used ND APIs and they resulted in high MP CPU.
As part of the fix, disabling the port again is prevented if the port is already in the disabled state.
prod00271914
11.  
On a vADC and standalone, entering the command blkport disable caued a panic.
prod00270629
12.  
Using WBM, the user lost access to a vADC.
prod00270705
13.  
Was unable to install a legacy compression license on top of NG/NG+.
prod00271476
14.  
The binary health check failed with a timeout even through the checked server replied with unexpected value.
prod00271032
15.  
Using WBM, Alteon panicked when generating techdata.
prod00271198
16.  
When a user tried to configure a group "metric response" with the dynamic weight SNMP health check, a warning message was issued.
prod00268995
17.  
After enabling compression, file download failed.
prod00272069
18.  
The VRRP backup sent advertisements after failover.
prod00271940
19.  
The EDNS+Source network-based name resolution failed for certain source addresses. The GSLB query failed when it contained the EDNS extension with the client subnet address, which fails to match the network class configuration.
prod00270636
20.  
When switching from an ADC-VX/vADC form factor to Standalone, the device became unresponsive.
prod00270987
21.  
The "new cached bytes" field in the statisctics for the acceleration engine cache mechanism, displayed the wrong value.
prod00271363
22.  
After a vADC rebooted from a panic, that part of the configuration was lost.
prod00271642
23.  
Using WBM, when adding interfaces to a VM, Flow Continutation Ingress ports could not be validated.
prod00256871
24.  
If a bandwidth management contract is associated to a traffic pattern and the TOS overwrite feature is enabled, a packet capture did not reflect the DSCP field modification.
prod00269734
25.  
In a BGP environment, when network class changes were applied, the device panicked.
prod00270640
26.  
On an Alteon D 6024 platform, could not assign more than 7200 CPS with the entire 40 CU.
prod00270007
27.  
When trying to open WAF, received a 50x error in the browser.
prod00271715
28.  
When running a vDirect script in Alteon, received a timeout.
prod00270578
29.  
After upgrading from version 30.5.8.0 to 31.0.9.0, vADC-1 booted with configuration in diff. The configuration could be applied but generated the following error:
ERROR mgmt: Error: Save not done. Application services engine is not synchronized with the current configuration.
prod00271383
30.  
In an ADC-VX environment, the WBM, SSH, and console were not available until device was rebooted.
prod00270986
31.  
Using SLB monitoring with API calls, the status of a real server that was part of a content rule and its health check failure reason could not be fetched using the API SlbStatEnhContRuleActionGroupEntry.
prod00269948
32.  
Policy Distribution replicated Session Filter Refinements with cookies not bound to any tunnel or host.
prod00269607
33.  
After rebooting the device, with configuration changes in diff, received errors after Apply.
prod00270462
34.  
Using WBM, the dashboard displayed the wrong throughput for a virtual server, even though here was no traffic for the virtual server.
prod00270094
35.  
When the filter action was "nat", the client NAT IP address options were missing from the Dynamic NAT tab
prod00272348
36.  
With reverse ena under filter and vmasport enabled, the return traffic was not undergoing server processing/NATing, causing the server packets seen on client network.
prod00272531
37.  
The Alteon secondary device was inaccessible via the mgmt port and console.
prod00271295
38.  
The STG-VLAN configuration failed to apply on reboot because the number of parameters exceeded 64.
Fix: After upgrade, perform the configuration and save, then reboot.
prod00271340
39.  
WBM did not display the virtual service configuration after synchronization.
prod00270170
40.  
Updated the online help for IPv6 local networks to "rem6 <Local Network v6 Address entry index>" / "rem <Local Network v4 Address entry index> .